Operating Range | The maximum range over which a monotonic output can be observed. |
Linear Range | The maximum range over which the deviation of the output from a linear best fit is within a specified percentage value. |
Linearity | The maximum deviation from a linear output as a percentage of the measurement range. |
Repeatability | The maximum deviation in output when the sensor is tilted and then returned to its original position. |
Resolution | The minimum incremental position change that generates a monotonic output. |
Symmetry | The maximum deviation in output between two symmetrical positions on either side of null. |
Maximum Current at Null | The maximum recommended current through the sensor at null at 23° C which will not cause damage to the sensor. |
Null Impedance | The impedance between the outer electrodes when the sensor is in the null position at 23° C. |
Operating Temperature | The temperature range over which typical output behavior is observed. |
Storage Temperature | The temperature range that will not physically or chemically alter the sensor while it is not in use. |
24 Hour Stability | The maximum variation in sensor output over a 24 hour period while the sensor remains stationary at null. |
Null Temperature Coefficient | The maximum output change at null per degree of temperature change above or below 23° C. |
Scale Temperature Coefficient | A coefficient to compensate for the change in gain caused by variations in temperature from 23° C. |
Null Offset | The maximum deviation between the electrical null of the sensor and mechanical null where the sensor is parallel to the surface of the earth. |
Cross Axis Error | Maximum deviation of the output on one axis while tilting along the perpendicular axis. |
Time Constant | The amount of times it takes the sensor to output a value which is at least 63.2% of the final output. |