New! Televac MX7M Cold Cathode Ionization Gauge

Part Number: 2-8950-XXXX

The new MX7M is an active vacuum gauge (also called an analog vacuum gauge or a digital vacuum gauge) featuring the new Televac® 7M cold cathode ionization gauge, which has a wide operating range of 5*10-11 to 1*10-2 Torr (if you want to convert this to another unit of measurement check out our handy unit converter). This is the only cleanable cold cathode on the market which measures into the 10-11 Torr range. The new triple inverted magnetron design improves the overall accuracy of the vacuum gauge by improving linearity while significantly decreasing the stray magnetic field.

This vacuum gauge has all metal seals, minimizing outgassing while maintaining a compact overall design. The MX7M cold cathode gauge also has a variety of features including a configurable 0 to 10 V DC analog output, RS-485 communications (EthernetIP optional), two programmable set points (relays and open collectors), and a bright OLED display with a 180° viewing angle.

All features of this cold cathode gauge are accessible through the display and touch controls or through the digital communications. Note that we also have an EthernetIP gateway for this active gauge which enables EthernetIP communication with a Rockwell Automation® Allen-Bradley® PLC. Combining this cold cathode gauge with a rough vacuum gauge such as the MX2A or MX4A will provide full range measurement from 5*10-11 Torr to 1000 Torr (slightly above atmosphere).

MX7M Analog and Digital Vacuum Gauge Features

  • Highly contamination resistant cold cathode ionization gauge design
  • All metal seals leading to low outgassing
  • Compact design
  • Color OLED display
  • Configurable 0 to 10 V analog output
  • Set point relay and open connector for process control
  • RS-485 and USB communications standard
  • EthernetIP communications available via the MX Active Gauge EIP Gateway
  • Easily cleaned ionization gauge for extended sensor lifetime
  • Rapid turn-around for calibration and service
MX7M Active GaugePart NumberPriceBuy
KF16 SST2-8950-KF16$1,100.00

KF25 SST2-8950-KF25$1,100.00

KF40 SST2-8950-KF40$1,100.00

CF40 Fixed SST2-8950-CF40$1,150.00

Wall Power SupplyPart NumberPriceBuy
100-240 V AC/47-63 Hz, plug types A, C, G, I2-7900-097$120.00
Operating Range 5*10-11 Torr to 1*10-2 Torr
Display OLED
Digital Communications RS-485, USB (micro)
Analog Output Configurable 0 to 10 V DC
Programmable Set Points 2
Set Point 1 Open collector
Set Point 2 Relay
Supply Voltage 22 V to 26 V DC
Maximum Power 8 W
Calibration Medium Dry air or nitrogen
Overpressure 150 psi
Digital Output Resolution 3 significant digits with exponent
Analog Output Resolution 16 bits
Operating Temperature 0 °C to 50 °C
Storage Temperature -20 °C to 60 °C
Bakeout Temperature 250 °C
Response Time ≤ 50 ms
 
Accuracy
1×10-9 to 1×10-3 Torr ±30% of reading
Analog Output ±10 mV
Display Readable Distance 3 m (10 ft)
Physical Characteristics
Enclosure Aluminum
Weight with Sensor 1 kg (2 lbs)
Weight without Sensor 0.3 kg (0.6 lbs)
Dimensions See dimensional drawing

Related Products

MX2A Thermocouple MX4A Convection MX7B Cold Cathode CC-10 Wide Range
Measurement Range 1*10-4 to 1000 Torr 1*10-4 to 1000 Torr 1*10-8 to 1*10-3 Torr 1*10-9 to 1000 Torr
Communications RS-485 RS-485 RS-485/USB RS-485
Analog Output Configurable 0 to 10 V DC Configurable 0 to 10 V DC Configurable 0 to 10 V DC Configurable 0 to 10 V DC
Programmable Set Points 2 2 2 3 relays
EthernetIP Available Yes Yes Yes No