Televac® 7B Cold Cathode Gauge (Penning Ionization Gauge)

Part Numbers: 2-2100-263, 2-2100-265, 2-2100-266, 2-2100-272


Compatible With: MX200, MX200 EthernetIP, MX7B


Features and Benefits:

  • Low cost vacuum gauge
  • Easily cleaned vacuum gauge for extended sensor lifetime
  • Durable Penning ionization gauge construction
  • Reliable cold cathode ionization gauge technology
  • Contamination resistant, resistant to inrushes of gas, and cleanable
  • Mountable in any orientation
  • Excellent customer support

The Televac® 7B cold cathode gauge (also called a Penning ionization gauge or cold cathode ionization gauge) has a measurement range from 10-7 Torr up to 10-3 Torr. This vacuum gauge makes indirect absolute pressure measurements by ionizing gas in the presence of a magnetic field. Unlike hot filament vacuum gauges, the 7B is cleanable, contamination resistant, and isn’t as easily damaged by inrushes of gas.

The design of this vacuum gauge allows for easy disassembly, enabling quick cleaning and extended use. The 7B Penning ionization gauge can be operated by the Televac® MX200 rack-mountable controller or as an active gauge via the MX7B. Any vacuum controller will automatically operate the 7B to provide a full-range vacuum measurement solution (from atmosphere/760 Torr to 10-7 Torr) when the 7B is used in conjunction with rough vacuum sensors like the 2A or 4A. Active vacuum gauges can also be combined using the MX2A/MX4A and MX7B to provide full-range vacuum measurement.

Image7B Penning Magnetron Cold CathodePart NumberPriceBuy
7B Penning Magnetron Cold Cathode - 3/4” NPT Brass
3/4” NPT Brass2-2100-263$400.00
7B Penning Magnetron Cold Cathode - 1” Straight Brass
1” Straight Brass2-2100-265$530.00
7B Penning Magnetron Cold Cathode - 1 ¼” Straight Brass
1 ¼” Straight Brass2-2100-266$525.00
7B Penning Magnetron Cold Cathode - NW25 (DN25 ISO-KF) Stainless Steel
NW25 (DN25 ISO-KF) Stainless Steel2-2100-272$525.00
ImageReplacement PartsPart NumberPriceBuy
Part Number: 2-6200-037 - 7B Cold Cathode Anode Assembly
Anode assembly2-6200-037$95.00
Part Number: 1-4210-50 - O-Ring for the 7B Cold Cathode Vacuum Gauge
O-Ring1-4210-50$4.05
7B Replacement Parts - Red cap
Red cap6-4210-25$1.40
Operating Range 1*10-7 Torr to 1*10-3 Torr
Analog Output Controller dependent
Supply Voltage Controller dependent
Mounting Orientation Any
Calibration Medium Dry air or nitrogen
Overpressure 150 psi
Analog Output Resolution Controller dependent
Operating Temperature 0 °C to 50 °C
Storage Temperature -20 °C to 70 °C
Bakeout Temperature 120 °C
Response Time ≤ 50 ms
Accuracy 1*10-6 Torr to 1*10-3 Torr: ± .2 decade

Analog Output Behavior